Home > Computer Tutorials > Troubleshooting > What are the common computer motherboard fault codes? What are the meanings of computer motherboard fault codes?

What are the common computer motherboard fault codes? What are the meanings of computer motherboard fault codes?

WBOY
Release: 2024-07-29 18:24:13
Original
507 people have browsed it

Troubleshooting: Common computer motherboard fault code meanings When the computer motherboard fails, it will remind the user through a series of fault codes. These codes are usually displayed on the motherboard's LED lights or in the BIOS settings, helping users quickly identify the source of the fault. This article is brought to you by Baicao, the editor of PHP, which sorts out common computer motherboard fault codes and their meanings to guide you in quickly solving computer problems. Continue reading for details below to learn about these fault codes so that you can promptly handle motherboard failures and restore normal operation of your computer.

What are the common computer motherboard fault codes? What are the meanings of computer motherboard fault codes?

1. What are the common computer motherboard fault codes? What are the meanings of computer motherboard fault codes?

1. From a series of codes (excluding "00" and "FF") to "FF" or "00", the motherboard self-test has passed, OK.

2. If "00" is output and the code does not change, the motherboard is not running. Check whether the CPU is broken, the CPU jumper, or whether the CPU settings are correct, whether the power supply is normal, and whether there is mold on the motherboard battery, etc.?

3 . If you set the CMOS to not prompt errors, when encountering a non-fatal fault, the diagnostic card will not stop and continue to go back to "00". The solution is to change the CMOS setting to prompt all errors and then turn on the computer. , if there is a non-fatal fault at this time, it will stop and then troubleshoot according to the code.

2. Computer fault codes: How to understand and solve common computer fault problems

Computer fault code analysis

In the process of daily use of computers, we sometimes encounter various fault problems. These problems are often accompanied by specific error codes that may seem meaningless to the average user. Next, we will analyze some common computer fault codes and explore ways to solve these problems.

Blue Screen Fault Code

Blue Screen of Death is a common fault prompt in Windows systems. It is usually accompanied by specific error codes, such as 0x0000007B, 0x00000024, etc. These codes usually indicate different types of system errors, which can be caused by hardware failures, driver issues, or software conflicts. To solve these problems, we can try to update drivers, repair system files, or troubleshoot hardware problems.

Network fault codes

When the network connection fails, we sometimes see error codes such as "DNS_PROBE_FINISHED_NXDOMAIN", "ERR_CONNECTION_TIMED_OUT" and so on. These codes imply problems with network connection or access to specific websites, which may be caused by DNS resolution failure, incorrect network settings, or network latency. We can solve these problems by clearing the DNS cache, changing the DNS server, or checking the network equipment.

Application fault codes

Many applications will generate error codes when running, such as "0xc000007b", "0xc0000005", etc. These codes often indicate corrupted program files, operating system permission issues, or memory access errors. To resolve these issues, we can try reinstalling the application, repairing operating system permissions, or performing a memory check.

Hardware fault code

Error codes caused by hardware faults are often hexadecimal numbers, such as "0x0000003B", "0x802B000A", etc. These codes may indicate hardware failure, such as memory module problems, hard drive failure, or other hardware damage. When facing these problems, we recommend performing hardware diagnosis or seeking professional hardware repair support.

In the daily use of computers, it is common to encounter fault codes, but we do not need to panic too much. By understanding the meaning of these codes, we can quickly locate the problem and take effective solutions. I hope this article can help you better understand computer fault codes and successfully solve computer fault problems.

Thank you for reading, I hope this article can help you solve computer problems!

3. What are the common fault codes for Gree air conditioners?

Gree air conditioners may also have problems of one kind or another in daily use. When a GREE air conditioner fails, the corresponding fault code will usually be displayed to tell us the specific cause of the failure and help us better identify the fault so that we can find a solution to the problem faster.

1. Gree air conditioner fault code table

2. Gree air conditioner common code analysis

1. E type fault code analysis

E1 system high voltage protection goes off for 3S and flashes 1 time

E2 indoor side anti-freeze protection goes off for 3S and flashes 2 Times

E3 system low voltage protection goes off 3S and flashes 3 times

E4 compressor exhaust protection goes off 3S and flashes 4 times

E5 low voltage overcurrent protection goes off 3S and flashes 5 times

E6 communication failure goes off 3S and flashes 6 times

E7 mode conflict, off 3S flashes 7 times

E8 anti-high temperature protection off 3S flashes 8 times

E9 anti-cold wind protection off 3S flashes 9 times

E0 whole machine AC voltage drops and frequency reduction off 3S flashes 10 times

Gree air conditioner appears For E series codes, most do not need to contact after-sales service personnel for on-site inspection. The simpler solution is to turn off the air conditioner internal unit, wait for a period of time and then turn it back on. The problem can usually be solved by itself.

2. H class fault code analysis

H1 defrost (defrost is not a malfunction) OFF 3S flashes 1 time

H2 electrostatic dust removal protection OFF 3S flashes 2 times

H3 compressor overload protection OFF 3S flashes 3 times

H4 system abnormality off 3S flashing 4 times

H5 module protection off 3S flashing 5 times

H6 no indoor motor feedback off 3S flashing 6 times

H7 synchronization failure off 3S flashing 7 times

H8 water full protection off 3S flashing 8 times

H9 electric heating tube failure, off 3S flashing 9 times

H0 heating anti-high temperature frequency reduction off 3S flashing 10 times

H series code appears in Gree air conditioner, H1-H8 can also be solved by shutting down and restarting, H9 and H0 It may be that the internal parts are damaged and you need to contact after-sales service for on-site inspection and repair.

3. Class F fault code analysis

F1 indoor environment temperature sensor package is on, short circuit is off and flashes 1 time for 3S

F2 indoor evaporator temperature sensor package is on, short circuit is off and flashes 2 times for 3S

F3 outdoor environment temperature sensor package On, short circuit off 3S flashes 3 times

F4 outdoor condenser temperature sensor package is on, short circuit off 3S flashes 4 times

F5 outdoor exhaust temperature sensor package is on, short circuit off 3S flashes 5 times

F6 Refrigeration overload frequency reduction Off 3S flashes 6 times

F7 Refrigeration oil return off 3S flashes 7 times

F8 Current is too large, reduce frequency, off 3S flashes 8 times

F9 Exhaust is too high, reduce frequency, off 3S flashes 9 times

F0 system is lack of fluorine or Blockage protection extinguishing 3S flashes 10 times

F series code appears in Gree air conditioner, which must be handled accordingly according to code analysis.

4. Class C fault code analysis

C1 arc protection off 3S flashes 12 times

C2 leakage protection off 3S flashes 13 times

C3 misconnection protection off 3S flashes 14 times

C5 jump cap fault protection off 3S Blinks 15 times

C6 without ground wire off 3S flashes 16 times

C series code appears on Gree air conditioner. First, turn off the air conditioner, disconnect the power supply, contact Gree after-sales service, and arrange for professional personnel to come for maintenance.

I am your friend @家电兰哥, focusing on sharing knowledge on purchasing and using household appliances. If you find it useful, please "like + collect + follow" three times in a row. Your encouragement is my motivation to continue sharing, 3Q!

4. Common fault codes for Kelon refrigerators?

The common fault code of Kelon refrigerator is E2. 1. Kelon refrigerator BCD-209W/HM refrigerator displays E2: Refrigerator compartment evaporator sensor failure.

2. Replacement method:

1: Remove the back cover

2: Remove the sensor fixing pad

3: Pull out the sensor from the back

4: Remove the sensor cable on the thermostat

5: Connect the new Insert the sensor into the refrigerator from the back

6: Fix the sensor

7: Install the back cover

8: Wire the sensor

9: Start up

5. Computer CPU fault code?

Blue screen error code caused by high CPU temperature: 0x0000008E (0xc0000005, 0x00000000, 0XAAD2AA28, 0x00000000)

This situation is generally caused by system software, memory, and hard disk. 1. The computer is accidentally installed with malware, or malicious programs are generated while surfing the Internet. It is recommended to use software such as 360 Defender and Kingsoft Defender to clean up junk and kill malware, which may solve the problem. If it doesn't work, reinstalling and restoring the system can solve the problems caused by the software.

6. Rotork common fault codes?

1. There are many common fault codes for Rotork robots. 2. The Rotork robot system is complex, and a variety of fault codes will appear during work, such as common motor fault codes, communication fault codes, static deviation fault codes, etc. These fault codes may occur during robot operation and need to be diagnosed and solved based on the corresponding fault codes. 3. Rotork robots have the characteristics of high performance, high reliability and high stability, but due to the complexity of its system, if a fault code occurs, corresponding repairs and maintenance are required. Therefore, it is very important for maintenance personnel to understand common Rotork robot fault codes.

7. Common fault codes of Yangli punch press?

In the operation of Yangli punch press, common fault codes and related fault problems may include the following:

1. E001: The safety door is not closed or locked properly. The solution is to close the safety door and make sure it is properly locked.

2. E002: The emergency stop button is pressed or malfunctions. The solution is to release the emergency stop button and check if there is a fault.

3. E003: There is no material bite (material loss) signal. This may be caused by a malfunction in the material supply system or a faulty sensor. The solution is to check that the supply system and sensors are working properly.

4. E004: Unloading sensor failure. This may be caused by a poor connection or malfunction of the sensor. The solution is to check the sensor connections and make sure they are functioning properly.

5. E005: Upper mold limit failure. This may be caused by a faulty or improper adjustment of the upper mold limit switch. The solution is to check the limit switch and make necessary adjustments.

6. E006: Lower mold limit failure. Similar to the upper mold limit failure, but occurs on the lower mold. The solution is to check the limit switch and make necessary adjustments.

7. E007: Upper mold sensor failure. This may be caused by a poor connection or malfunction of the sensor. The solution is to check the sensor connections and make sure they are functioning properly.

8. E008: Lower mold sensor failure. Similar to the upper mold sensor failure, but occurring on the lower mold. The solution is to check the sensor connections and make sure they are functioning properly.

These fault codes and problems are only some of the possible situations. The specific fault problems and solutions may vary depending on different Yangli punch press models and manufacturers. If you encounter a fault, please refer to the user manual of the relevant device or contact professional technicians for resolution.

8. What are the common fault repair codes for kstarups power supplies?

1. Code 11: Battery circuit is disconnected.

This code indicates that the QF1 switch on the battery circuit is disconnected or the battery circuit is disconnected. This error can be detected by measuring the voltage on the QF1 line. When the UPS is on and the charger is stopped, you can measure the battery voltage at this time.

Battery voltage

2. Code 12: The battery needs to be tested.

This code will be displayed when the battery life recorded in the battery life counter has ended, the automatic battery test (open circuit voltage test) has failed, or the automatic battery test (partial discharge test) has failed.

This error is easy to remember and can only be solved by "Reinitialize" in the "Command" menu of "Soft-tunor".

9. What are the common fault codes for washing machines?

Answer formula 1: There are many common fault codes for washing machines. Mainly because the washing machine has a long service life, it is inevitable that various faults will occur during use. When a fault occurs, the washing machine will generate different fault code prompts. Here are several common washing machine fault codes and their meanings: 1. E1: Indicates a high water level fault, which is caused by poor drainage of the washing machine. 2. E2: Indicates that the heater is faulty and you need to check whether the heater is damaged. 3. E5: Indicates that the water level sensor is abnormal, and it is necessary to check whether the sensor is faulty or whether the circuit is damaged. 4. E6: Indicates that the door lock signal is abnormal. It is necessary to check whether the door lock sensor is faulty or whether the door lock control circuit is damaged. To sum up, the common fault codes of washing machines mainly include the above types. When the fault code prompts, it is necessary to repair or replace the corresponding parts according to the specific cause of the fault.

10. What are the common fault codes of air conditioners?

E1: Press overcurrent, overheating, excessive exhaust, module protection;

E2: Indoor anti-freeze protection;

E3: Indoor temperature sensing package open, short circuit;

E4: Indoor pipe temperature open, Short circuit;

E5: indoor and outdoor communication failure.

: Fixed frequency machine fault code:

E1: Compressor high pressure protection

E2: Evaporator anti-freeze protection

E3: Compressor low pressure protection

E4: Compressor exhaust temperature too high protection

E5: Overcurrent (low voltage protection)

KF-60L WAK split cabinet room air conditioner fault code﹕

E1 1﹑There are obstacles in front of the condenser

2﹑The control circuit is normal

3﹑The outdoor ambient temperature is high Start cooling at 43 degrees

4﹑Excessive pressure in the high-pressure pipe causes the high-pressure switch to operate

E2 1﹑The indoor fan does not turn or the air outlet is blocked

2﹑The indoor ambient temperature is lower than 18 degrees

3﹑Pipe temperature sensor The head is broken

4﹑The tube temperature sensing head plug is not plugged in properly

5﹑The control circuit is normal

6﹑Capacitor C7 is leaking

LF-12WAK split cabinet type room air conditioner fault code﹕

E1 1﹑ There are obstacles in front of the condenser

2﹑The control circuit is normal

3﹑The three-phase power supply is missing a phase

3﹑The cooling starts when the outdoor ambient temperature is higher than 43 degrees

4﹑The operating current is too high and the overprotector operates or Excessive pressure in the high-pressure pipe causes the high-pressure switch to operate

E2 1﹑The indoor fan does not rotate or the air outlet is blocked

2﹑The indoor ambient temperature is lower than 18 degrees

3﹑The pipe temperature sensor head is broken

4﹑The pipe temperature sensor The head plug is not inserted properly

5﹑The control circuit is normal

6﹑Capacitor C7 leakage Gree air conditioner fault code Gree: frequency converter cabinet E1-E5

E1: press overcurrent, overheating, exhaust too high, module protection ;

E2: Indoor anti-freeze protection;

E3: Indoor temperature sensing package is open, short circuit;

E4: Indoor pipe temperature is open, short circuit;

E5: Indoor and outdoor communication failure.

: Fixed frequency machine fault code:

E1: Compressor high pressure protection

E2: Evaporator anti-freeze protection

E3: Compressor low pressure protection

E4: Compressor exhaust temperature too high protection

E5: Overcurrent (low voltage protection)

KF-60L WAK split cabinet room air conditioner fault code﹕

E1 1﹑There are obstacles in front of the condenser

2﹑The control circuit is normal

3﹑The outdoor ambient temperature is high Start cooling at 43 degrees

4﹑Excessive pressure in the high-pressure pipe causes the high-pressure switch to operate

E2 1﹑The indoor fan does not turn or the air outlet is blocked

2﹑The indoor ambient temperature is lower than 18 degrees

3﹑Pipe temperature sensor The head is broken

4﹑The tube temperature sensing head plug is not plugged in properly

5﹑The control circuit is normal

6﹑Capacitor C7 is leaking

LF-12WAK split cabinet type room air conditioner fault code﹕

E1 1﹑ There are obstacles in front of the condenser

2﹑The control circuit is normal

3﹑The three-phase power supply is missing a phase

3﹑The cooling starts when the outdoor ambient temperature is higher than 43 degrees

4﹑The operating current is too high and the overprotector operates or Excessive pressure in the high-pressure pipe causes the high-pressure switch to operate

E2 1﹑The indoor fan does not rotate or the air outlet is blocked

2﹑The indoor ambient temperature is lower than 18 degrees

3﹑The pipe temperature sensor head is broken

4﹑The pipe temperature sensor The head plug is not inserted properly

5﹑The control circuit is normal

6﹑Capacitor C7 leakage Gree air conditioner fault code Gree: frequency converter cabinet E1-E5

E1: press overcurrent, overheating, exhaust too high, module protection ;

E2: Indoor anti-freeze protection;

E3: Indoor temperature sensing package is open, short circuit;

E4: Indoor pipe temperature is open, short circuit;

E5: Indoor and outdoor communication failure.

: Fixed frequency machine fault code:

E1: Compressor high pressure protection

E2: Evaporator anti-freeze protection

E3: Compressor low pressure protection

E4: Compressor discharge temperature too high protection

E5: Overcurrent (low voltage protection)

KF-60L WAK split cabinet room Air conditioner fault code﹕

E1 1﹑There is an obstacle in front of the condenser

2﹑The control loop is normal

3﹑The cooling starts when the outdoor ambient temperature is higher than 43 degrees

4﹑Excessive pressure in the high-pressure pipe causes the high-pressure switch to operate

E2 1﹑The indoor fan does not turn or the air outlet is blocked

2﹑The indoor ambient temperature is lower than 18 degrees

3﹑The tube temperature sensor head is broken

4﹑The tube temperature sensor head plug is not plugged in properly

5 ﹑Control loop is normal

6﹑Capacitor C7 leakage

LF-12WAK split cabinet room air conditioner fault code﹕

E1 1﹑There are obstacles in front of the condenser

2﹑Control loop is normal

3﹑ The three-phase power supply is missing a phase

3﹑Cooling starts when the outdoor ambient temperature is higher than 43 degrees

4﹑Excessive operating current causes the overprotector to operate or excessive pressure in the high-pressure pipe causes the high-voltage switch to operate

E2 1﹑The indoor fan does not rotate or The air outlet is blocked

2﹑The indoor ambient temperature is lower than 18 degrees

3﹑The tube temperature sensor head is broken

4﹑The tube temperature sensor head plug is not plugged in properly

5﹑The control loop is normal

6﹑Capacitor C7 Leakage Gree air conditioner fault code Gree: Frequency conversion cabinet E1-E5

E1: Press overcurrent, overheating, excessive exhaust, module protection;

E2: Indoor anti-freeze protection;

E3: Indoor temperature sensing The package is open, short circuit;

E4: The indoor pipe is warm and open, short circuit;

E5: Indoor and outdoor communication failure.

: Fixed frequency machine fault code:

E1: Compressor high pressure protection

E2: Evaporator anti-freeze protection

E3: Compressor low pressure protection

E4: Compressor exhaust temperature too high protection

E5: Overcurrent (low voltage protection)

KF-60L WAK split cabinet room air conditioner fault code﹕

E1 1﹑There are obstacles in front of the condenser

2﹑The control circuit is normal

3﹑The outdoor ambient temperature is high Start cooling at 43 degrees

4﹑Excessive pressure in the high-pressure pipe causes the high-pressure switch to operate

E2 1﹑The indoor fan does not rotate or the air outlet is blocked

The above is the detailed content of What are the common computer motherboard fault codes? What are the meanings of computer motherboard fault codes?. For more information, please follow other related articles on the PHP Chinese website!

source:xtzjcz.com
Statement of this Website
The content of this article is voluntarily contributed by netizens, and the copyright belongs to the original author. This site does not assume corresponding legal responsibility. If you find any content suspected of plagiarism or infringement, please contact admin@php.cn
Popular Tutorials
More>
Latest Downloads
More>
Web Effects
Website Source Code
Website Materials
Front End Template